Cloud Acropolis Kaunas Data Center

Cloud Acropolis is ready to provide Cloud and Disaster Recovery services from its Green and Highly available Data center.

Cloud Acropolis has upgraded its DR site to a Rating 2 Standard. Our site is located in Kaunas, approximately 100 km from our main Vilnius site.

It has capacity of 4 racks, equivalent of 52 servers, 4100 CPU cores, 78 TB of RAM, 780 TB of pure Enterprise NVMe SSD storage.

This site adds up to our reliability pillar while respecting security and high performance. It is also connected to High Speed fibre internet, within anyone's reach.

Cloud Acropolis Disaster Recovery or High Availability site is managed by the same talented and experienced team. This site follows the exact same design and operational standards as our main site. It is in process to be added to our PCI DSS and ISO27001 scope.

100+ km Distance

Geographic separation from main site ensures business continuity during regional disasters

Rating 2 Standard
4
Racks
4,100
CPU Cores
78 TB
RAM
780 TB
NVMe SSD Storage

Power Infrastructure

From the physical point of view, the site has reliable power from the Lithuanian power grid with a ring connection, and already proven reliability for the past 2 years.

This power is backed up by a Generator and a diesel tank of 500 liters which can provide enough power for more than 5 days at full load. As per actual tests, within the actual load we have a capacity of over 3 weeks.

Automatic Transfer Switch (ATS)

The main city power and Generator are managed by an ATS. From the time the main power is cut till the load is put on running generator, we only need 10 seconds.

Phase Distribution

From the main distribution panel, we segregate all three power phases:

  • Phase 1: Feeds UPS A for IT equipment power A
  • Phase 2: Feeds UPS B for IT equipment power B
  • Phase 3: Powers AC and general power

Double Conversion UPS System

There are 2 double conversion UPS systems feeding each power line in each rack. All IT equipment are fed via the batteries only in a totally segregated clean way at 230V 50 Hz.

Each UPS is connected to 20 batteries, and has a power capacity of 3 hours at 80% load. Our DR site has a capability of 6 hours of clean UPS power.

The power has been designed in a full modular, redundant and segregated manner. It has its own dedicated room with dual AC and fire suppression.

6 Hours

UPS Power Capacity

230V 50Hz

Clean Power

40 Batteries

Total Backup

Double Conversion

UPS Type

Data Center Infrastructure

When it comes to the data center itself we have full redundancy at all levels. Each rack is fed by 2 independent and clean power supplies (UPS). There is 2N cooling system. To align with Green implementation, we have setup cold aisle containment.

The network is set in a separated rack to ensure the access to the equipment is done by the right expertise.

TIA 942 Rating 4

Structured cabling follows highest standards

SAN & Ceph Storage

Fully redundant storage infrastructure

Environmental Monitoring

Leak detection, temperature and humidity monitoring

CCTV Monitoring

Full monitoring inside and outside the building

Data Center Features

High Efficiency & Performance

Our datacenter is a Rating 4 facility based on TIA 942, meaning all components are fully redundant and fault tolerant. Designed for optimal efficiency and performance.

Maximum Physical Security

The data center is under heavy 24/7 surveillance with closed circuit CCTV and round the clock guarded security staff. As an ISO27001 certified facility, we closely audit access logs to ensure only authorized personnel have access.

Compliance & Standards

ISO 27001
Certified
PCI DSS
In Progress
ISO 9001
Certified
TIA 942
Rating 2